[PATCH] A couple more GND-stitch vias Undo converting GND to GND_JMP and fix everything that broke From 969311f00cbb6d6ece9a25b5fb1d4e2884e468c0 Mon Sep 17 00:00:00 2001 Subject: [PATCH] adds ideas for a single 0.25 mm² wire, reinforced insulation, conductor diameter 0.9mm, outer diameter 2.1mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00045_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO THT Terminal Block Phoenix MKDS-1,5-2-5.08 pitch 5.08mm size 40.6x10.6mm^2 drill 1.3mm pad.