Close Testing before powering up: Clock In - ~27K to U3-8? No, transistors maybe activate? - Clock In Normal - 1k to U2-8 (AND NOT short to U2-10 - Clock Rate - variable resist +6k between U2-8 and U2-9 Reset Sw - when pressed, short +12V and Reset In socket Reset Socket to U3-3 = capacitor measurement roughly 15nF (has a resistor as well - Once/Cont 11 Toggle Switches, 2pin: - Glide attenuator (B10k) (join two left pins from below Clock POT is too small for a single 1 mm² wires, reinforced insulation, conductor diameter 1.7mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator ipc_noLead_generator.py Texas QFN, 14 Pin (JEDEC MO-153 Var JD https://www.jedec.org/document_search?search_api_views_fulltext=MO-153), generated with kicad-footprint-generator Hirose DF11 through hole, DF11-26DP-2DSA, 13 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator connector JST LEA top entry JST AUH series connector, S10B-J21DK-GGXR (http://www.jst-mfg.com/product/pdf/eng/eJFA-J2000.pdf), generated with.