To U2-10 - Clock Rate - variable resist +6k between U2-8 and U2-9 - Reset Socket to U3-3 = capacitor measurement roughly 15nF (has a resistor as well Once/Cont When in Cont mode shorts Casc Out - Diode from rotary pin 13? CV Out - Diode from rotary pin 13 - CV Range - Once/Cont 11 Toggle Switches, 3pin: 11 Toggle Switches, 2pin: - step - reset in - CV Range - Once/Cont When in Cont mode shorts Casc Out normal to Reset In - ~27K to U3-8? No, transistors maybe activate? Clock Out - 1K to U2-14 - Casc out 2x Toggle Switches, 3pin: 11 Toggle Switches, 2pin: - Glide attenuator (B10k) (join two left pins from below - Glide, manual (A100k) (two left pins, from below) Pots, 2-pin: - Glide, manual (A100k) (two left pins, from below Clock rate goes down when resistance goes up, opposite to expectation. C1 is too small; need more than fifty.