3
1
Back

Wired Open-Loop Current Sensor LEM CKSR 6/15/25/50/75-NP Current Transducer, https://www.lem.com/sites/default/files/products_datasheets/cksr_75-np.pdf LEM HO 40/60/120/150-NP Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/la_25-p.pdf LEM current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf LEM HX03-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf LEM HX25-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf LEM HX50-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%205_15-np_e%20v10.pdf LEM HX10-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf LEM HX04-P hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf LEM HX03-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf LEM HX25-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf LEM HX15-NP hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf LEM HX03-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf LEM HX03-P-SP2 hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf LEM Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/ho-nsm-0000_series.pdf LEM HO 8/15/25-NP Current Transducer (https://www.lem.com/sites/default/files/products_datasheets/ho-np_0100__1100_series.pdf LEM HTFS x00-P current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%203_50-p_sp2_e%20v07.pdf LEM HX04-P hall effect current transducer (https://www.lem.com/sites/default/files/products_datasheets/hx%202_6-p_e%20v5.pdf LEM HX05-NP hall effect current transducer LEM_LTSR-NP 5V supply voltage series https://www.lem.com/sites/default/files/products_datasheets/ltsr_6-np.pdf DFN, 4 Pin (https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/0_Datasheets/Humidity/Sensirion_Humidity_Sensors_SHTC3_Datasheet.pdf Sensirion DFN-8 SHT3x-DIS (https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/2_Humidity_Sensors/Datasheets/Sensirion_Humidity_Sensors_SHT3x_Datasheet_digital.pdf 24-Lead Plastic QFN (4mm x 4mm) (see Linear Technology DFN_10_05-08-1722.pdf DFN, 10 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/3471fb.pdf#page=15), generated with kicad-footprint-generator Molex Mini-Fit Jr. Power Connectors, old mpn/engineering number: 5566-18A, example for new mpn: 39-28-914x, 7 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xx-dv-xe-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-thru.pdf), generated with kicad-footprint-generator ipc_gullwing_generator.py TSSOP, 16 Pin (https://www.analog.com/media/en/technical-documentation/data-sheets/HMC7992.pdf), generated with kicad-footprint-generator Soldered wire connection, for 6 times 0.5 mm² wires, reinforced insulation, conductor diameter 2.4mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix THT Terminal Block pitch 10.00mm diameter 22mm height 40mm Electrolytic.

New Pull Request