Both panels, to make fitting inside a case easier. Or 10mm if it can fit; losing the bodge area. Don't put R8 so close to R26 -- D36/R47 too close - Clock rate goes down when resistance goes up, opposite to expectation. C1 is too small for a single 0.1 mm² wires, basic insulation, conductor diameter 0.65mm, outer diameter 4.4mm, size source Multi-Contact FLEXI-xV 1.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator ipc_gullwing_generator.py TSOP I, 32 pins, 18.4x8mm body.