Bugfix/v1.1 Add note resulting from real TL0x4, fix pots being backwards, tighten up schematic, fit letter instead of latch, https://www.neutrik.com/en/product/nc3fahr2-0 A Series, 4 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel. - Current design uses six IDC 2×8 connectors with 4 positions D 3 rotary switches are actually 2p6t, which means only six different step counts are available until the replacement arrives - Wiring SW15 (once/stop) and cascade out is easier done via skywiring; only one side when convenient. You can view the terms and.