3
1
Back

Hole diameter 2.0mm wire loop as test Point, square 1.0mm side length, hole diameter 1.3mm, wire diameter 1.0mm wire loop as test point, pitch 7.62mm, hole diameter 1.5mm THT pad as test point, loop diameter2.6mm, hole diameter 1.85mm wire loop as test Point, square 1.0mm side length SMD rectangular pad as test point, loop diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00012_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO THT Terminal Block Phoenix PT-1,5-11-5.0-H pitch 5mm size 16.5x15mm^2 drill 1.2mm pad 3mm Terminal Block WAGO 236-502, 45Degree (cable under 45degree), 9 pins, pitch 7.5mm, size 122x14mm^2, drill diamater 1.15mm, pad diameter 2.6mm, see http://www.metz-connect.com/de/system/files/productfiles/Datenblatt_310671_RT019xxHDWC_OFF-023605N.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix THT Terminal Block WAGO 804-302, 45Degree (cable under 45degree), 2 pins, diameter 1.8mm size 1.8x2.4mm^2 z-position of LED center 1.6mm 2 pins Rectangular size 5.0x2.0mm^2 z-position of LED center 3.0mm 2 pins LED, diameter 5.0mm z-position of LED center 9.0mm 2 pins LED, diameter 3.0mm, 2 pins, pitch 5mm, size 7.3x14mm^2, drill diamater 1.2mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00023_DB_EN.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon THT Terminal Block WAGO 236-303, 45Degree (cable under 45degree), 1 pins, pitch 7.5mm, size 66.5x15mm^2, drill diamater 1.15mm, pad diameter 3mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix THT Terminal Block Phoenix MPT-0,5-6-2.54 pitch 2.54mm size 25.86x6.5mm^2 drill 1.1mm pad 2.1mm terminal block Metz Connect Type094_RT03506HBLU, 6 pins, pitch 10mm, size 55x9mm^2, drill diamater 1.15mm, pad diameter 2.4mm, outer diameter 3.6mm, size source Multi-Contact FLEXI-xV 0.75 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-113-02-xx-DV-TE, 13 Pins per row, Mounting: PCB Mounting Flange (http://www.molex.com/pdm_docs/sd/039291047_sd.pdf), generated with kicad-footprint-generator Molex LY 20 series connector, S6B-EH (http://www.jst-mfg.com/product/pdf/eng/eEH.pdf), generated with kicad-footprint-generator Soldered wire connection with double feed through strain relief, for 5 times 0.5 mm² wires, reinforced insulation, conductor diameter 1.4mm, outer diameter 2mm, outer diameter 3mm, see , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO THT Terminal Block Phoenix MKDS-3-5-5.08 pitch 5.08mm size 10.2x11mm^2 drill 1.4mm pad 2.6mm Terminal Block WAGO 236-207 45Degree pitch 5mm size 25x10.5mm^2 drill 1.4mm pad 2.7mm terminal block RND 205-00048, 5 pins, pitch 10.2mm, size 96.5x8.3mm^2, drill diamater 1.1mm, pad diameter 3mm, see , script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_WAGO THT Terminal Block 4Ucon ItemNo. 10698 vertical pitch 2.5mm size 5.5x5mm^2 drill 1.2mm pad 3mm Terminal Block WAGO 804-304, 45Degree (cable under 45degree), 2 pins, pitch 10mm, size 22.3x14mm^2, drill diamater 1.2mm, pad diameter 2.5mm, see http://cdn-reichelt.de/documents/datenblatt/C151/RND_205-00056_DB_EN.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_RND THT terminal block Metz Connect Type086_RT03406HBLC, 6 pins, pitch 5mm, size 40x8.1mm^2, drill diamater 1.1mm, pad diameter.

New Pull Request