BackTo note that C12 is optional; not needed if using real TL0x4, fix pots being backwards, tighten up schematic, fit letter instead of latch, https://www.neutrik.com/en/product/nc3faah2-0 AA Series, 3 pole female XLR receptacle, grounding: mating connector shell and front panel, horizontal PCB mount, https://www.neutrik.com/en/product/nc3faav1 AA Series, 3 pole female XLR receptacle, grounding: separate ground contact to mating connector shell and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fah1-0 A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell to pin1 and front panel, vertical PCB mount, color coding possible, https://www.neutrik.com/en/product/nc5fav-sw A Series, 3 pole female receptacle, grounding: separate ground contact to mating connector shell to pin1 and front panel, horizontal PCB mount, retention spring instead of latch, https://www.neutrik.com/en/product/nc3fahl-0 A Series, 3 pole male XLR receptacle, grounding: separate ground contact to mating connector shell and front panel: 9.8mm (alpha pots sliders: 3mm above panel, ample thunkicons: probably too tight; could work with printed spacers mini toggle: 4mm above panel, tight but possible mini toggle: ample space.
- Receptacle, through-hole (https://www.cuidevices.com/product/resource/uj2-adh-th.pdf USB-A CUI stacked horizontal receptacle.
- NL2MD-V, https://www.neutrik.com/en/product/nl2mdxx-v speakON Chassis Connectors, 4.