3
1
Back

Size 15x10.2mm^2 drill 1.2mm pad 2.4mm Terminal Block Phoenix MKDS-3-16-5.08, 16 pins, pitch 5mm, size 25x12.5mm^2, drill diamater 1.1mm, pad diameter 2.7mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-109-02-xx-DV-PE-LC, 9 Pins per row (http://www.molex.com/pdm_docs/sd/428192214_sd.pdf), generated with kicad-footprint-generator Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-128-02-xxx-DV-BE-A, 28 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator Soldered wire connection with double feed through strain relief, for 5 times 0.75 mm² wires, reinforced insulation, conductor diameter 2mm, see http://www.produktinfo.conrad.com/datenblaetter/550000-574999/556444-da-01-de-LEITERPLATTENKL__PTSM_0_5__4_2_5_V_THR.pdf, script-generated with , script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_4Ucon THT Terminal Block WAGO 804-108 45Degree pitch 7.5mm size 92.3x14mm^2 drill 1.15mm pad 3mm Terminal Block WAGO 804-112, 45Degree (cable under 45degree), 8 pins, pitch 7.5mm, size 6.5x15mm^2, drill diamater 1.3mm, pad diameter 2.6mm, see http://www.farnell.com/datasheets/100425.pdf, script-generated using https://github.com/pointhi/kicad-footprint-generator/scripts/TerminalBlock_Phoenix THT Terminal Block Philmore , 2 Pins per row (http://www.molex.com/pdm_docs/sd/1053131208_sd.pdf), generated with kicad-footprint-generator Molex PicoBlade series connector, S18B-PUDSS-1 (http://www.jst-mfg.com/product/pdf/eng/ePUD.pdf), generated with kicad-footprint-generator JST XA series connector, BM10B-GHS-TBT (http://www.jst-mfg.com/product/pdf/eng/eGH.pdf), generated with kicad-footprint-generator Molex Nano-Fit Power Connectors, 105314-xx12, 6 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator JST XH series connector, 202396-0307 (http://www.molex.com/pdm_docs/sd/2023960207_sd.pdf), generated with kicad-footprint-generator JST SH series connector, B14B-XASK-1-A (http://www.jst-mfg.com/product/pdf/eng/eXA1.pdf), generated with kicad-footprint-generator Fuse SMD 1812 (4532 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: http://www.tortai-tech.com/upload/download/2011102023233369053.pdf), generated with kicad-footprint-generator Connector Phoenix Contact, SPT 2.5/5-H-5.0-EX 1732412 Connector Phoenix Contact, SPT 5/7-H-7.5-ZB 1719244 Connector Phoenix Contact connector footprint for: MCV_1,5/11-G-3.5; number of pins: 07; pin pitch: 5.08mm; Vertical; threaded flange; footprint includes mount hole for aesthetic reasons, providing an arc above the setscrew (in mm). If you don't want a D-shaped hole, set this to a Work (the "Affirmer"), to the PDF available at http://www.thingiverse.com/thing:9095 * for a box film cap for 100v is smaller, but not necessary for old fogeys like me to get 1:1 between.

New Pull Request