3
1
Back

Don't put R8 so close to R26 -- D36/R47 too close Testing before powering up: Clock In Normal - 1k to U2-8 (AND NOT short to U2-10 - Clock rate goes down when resistance goes up, opposite to expectation. C1 is too small for a single 0.25 mm² wires, basic insulation, conductor diameter 0.5mm, outer diameter 1mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator Molex SPOX Connector System, 53048-0610, 6 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator Hirose DF13 through hole, DF13-09P-1.25DS, 9 Pins (https://www.molex.com/pdm_docs/sd/026605050_sd.pdf), generated with kicad-footprint-generator Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-111-02-xx-DV-TE, 11 Pins per row (http://suddendocs.samtec.com/prints/hle-1xx-02-xxx-dv-xx-xx-xx-mkt.pdf, http://suddendocs.samtec.com/prints/hle-dv-footprint.pdf), generated with kicad-footprint-generator Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-108-02-xx-DV-PE-LC, 8 Pins (http://www.molex.com/pdm_docs/sd/559350530_sd.pdf), generated with kicad-footprint-generator Soldered wire connection with feed through strain relief, for 4 times 0.1 mm² wires, reinforced insulation, conductor diameter 1.7mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times 2 mm² wire, reinforced insulation, conductor diameter 0.9mm, outer diameter 4.4mm, size.