3
1
Back

Resistance goes up, opposite to expectation. Glide fix glide fix - CV Range - Once/Cont When in Cont mode shorts Casc Out normal to Reset In socket - Reset Sw - when pressed, short +12V and Reset In - diode to U2-3 Clock In Normal - 1k to U2-8 (AND NOT short to U2-10 - Clock rate (B100k) (not sure yet which.