Down when resistance goes up, opposite to expectation. Schematic fixes: - C1 is too small; need more than 100k to get 1:1 between schematic and front panel, horizontal PCB mount, retention spring, no latch, https://www.neutrik.com/en/product/nc3fbv1-0 B Series, 3 pole male XLR receptacle, grounding: ground contact to mating connector shell and front panel, horizontal.