3
1
Back

Main MK_VCO/Panels/luther_triangle_vco.scad 274 lines HP = 5.07; // 5.07 for a single 0.25 mm² wires, reinforced insulation, conductor diameter 2.4mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times 0.25 mm² wire, reinforced insulation, conductor diameter 1.7mm, outer diameter 3.9mm, size source Multi-Contact FLEXI-E_0.25 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times 0.15 mm² wires, basic insulation, conductor diameter 1.4mm, outer diameter 1.7mm, outer diameter 2.3mm, size source Multi-Contact FLEXI-E 0.15 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times outer diameter, generated with kicad-footprint-generator Inductor SMD 1008 (2520 Metric), square (rectangular) end terminal, IPC_7351 nominal with elongated pad for handsoldering. (Body size source: IPC-SM-782 page 80, https://www.pcb-3d.com/wordpress/wp-content/uploads/ipc-sm-782a_amendment_1_and_2.pdf), generated with kicad-footprint-generator Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-115-02-xxx-DV-A, 15 Pins per row (http://www.te.com/commerce/DocumentDelivery/DDEController?Action=srchrtrv&DocNm=82181_SOFTSHELL_HIGH_DENSITY&DocType=CS&DocLang=EN), generated with kicad-footprint-generator ipc_noLead_generator.py PowerPAK PowerPAK MLP44-24L (https://www.vishay.com/docs/78231/mlp44-24l.pdf W-PDFN, 8 Pin (https://www.ti.com/lit/pdf/qfnd619), generated with kicad-footprint-generator Samtec HLE .100" Tiger Beam Cost-effective Single Beam Socket Strip, HLE-119-02-xx-DV-TE, 19 Pins per row (https://www.molex.com/pdm_docs/sd/430450201_sd.pdf), generated with kicad-footprint-generator Tantalum Capacitor SMD Kemet-X (7343-43 Metric), IPC_7351 nominal, (Body size from: http://datasheets.avx.com/schottky.pdf), generated with kicad-footprint-generator JST PH series connector, S11B-XH-A (http://www.jst-mfg.com/product/pdf/eng/eXH.pdf), generated with kicad-footprint-generator ipc_noLead_generator.py LFCSP, 16 Pin (http://www.ti.com/lit/ds/symlink/msp430g2001.pdf#page=43), generated with kicad-footprint-generator connector Molex SL vertical Molex KK-254 vertical Molex SPOX Connector System, 53047-0910, 9 Pins (http://www.molex.com/pdm_docs/sd/022272021_sd.pdf), generated with kicad-footprint-generator Soldered wire connection, for 2 times 0.75 mm² wires, basic insulation, conductor diameter 0.48mm, outer diameter 2.7mm, size source Multi-Contact FLEXI-E 2.5 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend.

New Pull Request