3
1
Back

6 2x8 IDC power connectors to supply Eurorack voltage. Updates to rev 2 beta by adding +5V, and both trigger/gate and CV on the wrong side of D35, but other options exist. Single-step button (SW13) isn't producing a high enough voltage to trigger steps. Replace C10 with 100K resistor, and bridge.