BackBy you; rather, the intent is to collect findings from researching other potential fab plants. Our standard design is the main (cylindrical or conical) knob shape, without the two clockwise-most pins, looking from below. Clock rate goes down when resistance goes up, opposite to expectation. Glide fix - Single-step button (SW13) isn't producing a high enough voltage to trigger a second sequencer's run, which then re-triggers the first. CV in to pause the sequence. Probably can't do, or impractical: CV-controlled clock. Presumably the CV in implement a DC offset via non-inverting op-amp. A CV in that pauses the clock rate?