Signals - Clock rate goes down when resistance goes up, opposite to expectation. C1 is too small for a single 0.25 mm² wires, basic insulation, conductor diameter 1.7mm, outer diameter 1.5mm, size source Multi-Contact FLEXI-xV 2.0 (https://ec.staubli.com/AcroFiles/Catalogues/TM_Cab-Main-11014119_(en)_hi.pdf), bend radius 3 times.